Share

Utopia IVX Premium

The most versatile VRF system

01

Eight spaces with different temperatures

Provides independent climate control in up to eight spaces, allowing different temperatures to be selected in each, without the need for the indoor units to be of the same type or power rating. Therefore, it adapts perfectly to the different temperature needs arising in any one space.

02

Lower power consumption

When the outside temperature is not extreme, the machine can optimise its power consumption by 50%. In addition, its 4-way valve also saves 43% on electric power, as it does not need electricity to keep operating in heating mode.

03

Wide range of power ratings

Its 9 power ratings, from 2 to 12 HP, make it the perfect solution for climate control in small and medium businesses with demanding requirements. To meet those demands, it can integrate air curtains and air conditioning units with DX-KIT software.

Technical data

Outdoor units

Maximum number of connected units
Power rating (min-max) CoolingkW
HeatingkW
Power consumption CoolingkW
HeatingkW
EER / COP
Perceived noise level (night mode)dB(A)
Airflowm³/h
Power feed
Diameter of pipes (liquid-gas)pulgada
Maximum length m
Maximum elevationm
Initial refrigerant charge (maximum length of unloaded piping)kg(m)
Additional refrigerant chargeg/m
Independent control
Refrigerant
Compressor
DimensionsHeightmm
Widthmm
Depthmm
KilogramsKg
RAS-2HVNP1 - Monofásica
2
5,00 ( 2,20 - 5,60)
5,60 (2,20 - 7,10)
1,17
1,13
Ver pdf
44(42)
2,436
1 ~ 230 V 50H
(1/4) - (1/2)
50
30/20
1,6 (30)
30
R410A
Scroll
600
792
300
43
RAS-2.5 HVNP1 - Monofásica
2
5,60 (2,20 - 6,30)
6,30 (2,20 - 8,00)
1,2
1,3
Ver pdf
45(43)
2,436
1 ~ 230 V 50H
(1/4) - (1/2)
50
30/20
1,6 (30)
30
R410A
Scroll
600
792
300
43
RAS-3HVNP1E - Monofásica
3
7,10 (3,20 - 8,00)
8,00 (3,50 - 10,60)
1,46
1,52
Ver pdf
46(42)
2,7
1 ~ 230 V 50H
(3/8) - (5/8)
50
30/20
2,3 (30)
40
R410A
Rotary
800
950
370
66
RAS-4HVNP1E - Monofásica
5
10,00 (4,50 - 11,20)
11,20 (5,00 - 14,00)
1,99
2,02
Ver pdf
47(43)
4,8
1 ~ 230 V 50H
(3/8) - (5/8)
75
30/20
4,1 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-5HVNP1E - Monofásica
6
12,50 (5,70 - 14,00)
14,00 (5,00 - 18,00)
3,11
2,91
3,81 / 4,55 ( A/B)
48 (44)
5,4
1 ~ 230 V 50H
(3/8) - (5/8)
75
30/20
4,2 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-6HVNP1E - Monofásica
6
14,00 (6,00 - 16,00)
16,00 (5,00 - 20,00)
3,94
3,61
3, 41 / 4,23 ( A/A)
48(45)
6
1 ~ 230 V 50H
(3/8) - (5/8)
75
30/20
4,2 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-4HNP1E - Trifásica
5
10,00 (4,50 -11,20)
11,20 (5,00-14,00)
1,99
2,02
4,68 /5,16 ( A/A)
47 (43)
4,8
3N ~ 400V 50Hz
(3/8) - (5/8)
75
30/20
4,1 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-5HNP1E - Trifásica
6
12,50 (5,70-14,00)
14,00 (5,00-18,00)
3,11
2,91
3,81/4,55 ( A/A)
48 (44)
5,4
3N ~ 400V 50Hz
(3/8) - (5/8)
75
30/20
4,2 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-6HNP1E - Trifásica
6
14,00 (6,00 -16,00)
16,00 (5,00-20,00)
3,94
3,61
3,41 /4,23 ( A/A)
48 (45)
6
3N ~ 400V 50Hz
(3/8) - (5/8)
75
30/20
4,2 (30)
60
R410A
Scroll
1,38
950
370
103
RAS-8HNPE - Trifásica
8
20,00 ( 8,00 - 22,40)
22,40 (6,30 - 28,00)
5,36
5,06
3,56/ 4,21 ( A/A)
57 (55)
7,62
3N ~ 400V 50Hz
03/08/2001
Requiere cálculo
30/20
5,7 (30)
100
R410A
Scroll
1,38
950
370
136
RAS-10HNPE - Trifásica
8
25,00 (10,00 - 28,00)
28,00 (8,00 - 35,00)
7,88
7,03
3,07/3,84 ( B/A)
58 (56)
8,04
3N ~ 400V 50Hz
01/02/2001
Requiere cálculo
30/20
6,2 (30)
100
R410A
Scroll
1,38
950
370
138
RAS-12HNP - Trifásica
8
30,00 (11,20 - 33,50)
33,50 (9,00 - 37,50)
11,05
8,96
2,65/3,64 ( D/A)
59 (57)
9,78
3N ~ 400V 50Hz
01/02/2001
Requiere cálculo
30/20
6,7 (30)
100
R410A
Scroll
1,65
1,1
390
168

Contact us

If you want to make an inquiry, write us