Monoduct RAD RPA Ducts

The most discreet air conditioning

01

Concealed installation

Monoduct RAD ducts are the ideal system to make use of air-conditioning pre-installations, since it is fitted into false ceilings. Their 4-metre extendible ducts allow a large volume of air to be distributed thanks to the high pressure switch, thus ensuring maximum comfort in any situation.

02

For all rooms

The option of selecting air inlet and outlet either through the rear or through the bottom of the outdoor unit makes the system fully adaptable to the structure of any building and room. In addition, the ducts can be half or fully opened or closed

03

The whole year round

Thanks to the built-in heat pump, your air-conditioner is the perfect substitute for heating if you do not live in an especially cold climate. The use it makes of energy from renewable sources helps to reduce your electricity consumption. In addition, it requires minimal maintenance.

Technical data

Outdoor units

Seasonal energy rating medium climate zoneCooling
Heating
Power feed
Power consumption (min - max)CoolingKW
HeatingKW
EER - COP (Cooling/heating energy performance)
SEER
SCOP (moderate climate zone)
Perceived noise levelCoolingdB(A)
HeatingdB(A)
Airflow Coolingm3/h
Heatingm3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum pipe lengthm
Maximum piping elevation (between indoor and outdoor units)m
Refrigerant chargekg (m)
Refrigerant
Compressor
DimensionsHeightmm
Widthmm
Depthmm
Weightkg
RAC-25NPA
A
A
220-240V, 1Ph, 50Hz
0,69 (0,15-1,05)
0,97 (0,11-1,40)
3,60-3,61 (A/A)
5,1
3,8
46
46
1620
1620
1/4 - 3/8
20
10
1,15 (20)
R410A
DC Twin Rotary
570
750
280
38
RAC-35NPA
A
A
220-240V, 1Ph, 50Hz
1,24 (0,15-1,28)
1,70 (0,11-1,92)
2,82-2,82 (C/D)
5,1
3,8
47
49
1620
1620
1/4 - 3/8
20
10
1,15 (20)
R410A
DC Twin Rotary
570
750
280
38
RAC 50NPA
B
A
220-240V, 1Ph, 50Hz
2,00 (0,15-2,06)
2,30 (0,11-2,53)
2,50-2,61 (E/E)
4,7
3,8
50
52
2160
2160
1/4 - 1/2
20
10
1,40 (20)
R410A
DC Twin Rotary
650
850
298
45
RAC-50DPA
A
A
220-230V, 1Ph, 50Hz
1,40 (0,20-2,10)
1,59 (0,20-2,20)
3,57-3,77 (A/A)
5,1
3,8
47
50
2700
2700
1/4 - 1/2
30
20
1,80 (30)
R410A
DC Twin Rotary
800
850
298
55
RAC-60DPA
B
A
220-230V, 1Ph, 50Hz
1,87 (0,20-2,50)
2,13 (0,20-2,60)
3,21-3,43 (A/B)
4,8
3,8
48
51
2700
2700
1/4 - 1/2
30
20
1,80 (30)
R410A
DC Twin Rotary
800
850
298
55
RAC-70DPA
B
A
220-230V, 1Ph, 50Hz
2,53 (0,20-2,92)
2,34 (0,20-3,10)
2,81-3,42 (C/B)
4,8
3,8
53
55
2820
2820
1/4 - 5/8
30
20
1,80 (30)
R410A
DC Twin Rotary
800
850
298
55

Indoor units

Power rating (min - max)CoolingKW
HeatingKW
Perceived noise level (very low - low - med - high)CoolingdB(A)
HeatingdB(A)
Noise level (Eurovent data) dB(A)
Air flow (very low - low - med - high)Coolingm3/h
Heatingm3/h
Diameter of pipes (liquid-gas) pulgadas
Condensate drain diameter mm
Remote control (standard)
Programming
DimensionsHeightmm
Widthmm
Depthmm
Weightkg
RAD-25RPA
2,50 (0,90-3,00)
3,50 (0,90-5,55)
29-31-34-36
27-30-33-37
57
330-390-450-510
360-420-480-600
1/4 - 3/8
16
Por cable
12h
235
750
400
19
RAD-35RPA
3,50 (0,90-4,00)
4,80 (0,90-6,60)
29-31-34-36
27-30-33-37
57
330-390-450-510
360-420-480-600
1/4 - 3/8
16
Por cable
12h
235
750
400
19
RAD-50RPA
5,00 (0,90-5,60)
6,00 (0,90-7,50)
29-32-35-38
29-32-35-38
58
330-360-450-510
360-420-480-630
1/4 - 1/2
16
Por cable
12h
235
750
400
19
RAD-50PPA
5,00 (0,90-6,00)
6,00 (0,90-7,00)
28-30-32-34
29-31-33-35
60
618-660-780-900
618-660-780-900
1/4 - 1/2
16
Por cable
12h
270
900
720
35
RAD-60PPA
6,00 (0,90-7,00)
7,30 (0,90-8,00)
28-30-32-34
29-31-33-35
60
618-660-780-900
618-660-780-900
1/4 - 1/2
16
Por cable
12h
270
900
720
35
RAD-70PPA
7,10 (0,90-8,00)
8,00 (0,90-9,00)
28-30-32-35
29-31-33-36
61
618-660-780-960
618-660-780-960
1/4 - 5/8
16
Por cable
12h
270
900
720
35

Documentation

Contact us

If you want to make an inquiry, write us